Application
1, Animal vaccine production: Avian influenza vaccine, Porcine PRRS vaccine, Foot-and-mouth disease, Rabies vaccine, Mink vaccine, DTP vaccine, Diphtheria vaccine, Tetanus vaccine, etc.
2, Human vaccine production: Diphtheria vaccine, Tetanus vaccine, Meningitis vaccine, Pneumonia IV vaccine, Hepatitis B vaccine, etc.
3, Culture for microorganism (bacterial,fungi,yeast.etc), mammalian cell(293,CHO etc.), plant cell, algae, enzyme, protein, additives, antibiotics etc.
Product Description
The main material is all stainless steel 316L tank body, there is no dead angle in the tank; it is equipped with special sampling and discharging valves for fermentation tanks, and transplanting pipes. It adopts a large viewing angle tank liquid level observation glass, 12V safety light, with temperature, PH, DO, defoaming, liquid level interface, inoculation port, feeding port, and multiple spare ports. All welds are strong, neat and beautiful. The tank body is designed with optimized diversion, which improves the exchange efficiency and the uniformity of the temperature in the tank.One way of deep ventilation is adopted, and the rotameter shows that the gas flow is adjusted according to the process requirements, and the air distributor in the tank distributes the gas evenly; the sterilizing filter (Dominic or Shanghai Yiming) with a precision of 0.2 μm is used to prevent material backflow device, ensuring safety and greatly extending service life
German Siemens S7-200 series PLC control system + 10” LCD touch screen display operation, on-site direct operation (menu type), full English menu and interface; sampling and display of tank data, browsing and analysis of system data, and reading settings. Available Control the stirring speed, the temperature of the medium in the tank, Ph value, DO value
Technical parameters
Total volume | 5L~1000L |
Working volume | 30%~70% |
Material | 316L stainless steel inside and 304 jacket |
Diameter: height | 1:2~3 |
Stirring system | Magnetic stirring or mechanical stirring one of the two optional 3 height adjustable stirrer |
Sterilization | On-site sterilization auto control or manual control |
Clean | Clean in place by spray ball |
Gas control | Manual control by rotor meter (standard) Auto control by mass flow meter( optional) |
Temperature control | Electric heating, water cooling, circulation pump temperature control |
Feeding | 4 fixed peristaltic pump( standard) Variable speed peristaltic pump(optional) |
Basic sensor | Stanaded with pH, DO, Temperature, Foam Optional: Liquid Level sensor, OD sensor, Turbidity sensor, ORP sensor, Weight system, Live cell sensor etc. |